Yaskawa J7 to J1000 User Manual
Page 14

(Header Title) Application Note
Doc#: PL.J1000.01 Copyright Yaskawa Electric America, Inc.©2008 www.yaskawa.com August 1, 2008 14 of 19
Subject: Transition Guide
Product: J1000
Document: PL.J1000.01
Title: Product Transition Guide – J7 to J1000
Product Transition Guide – J7 to J1000
J7
J1000
Drive
Function
/ Parameter
Parameter
No.
Initial
Value
Parameter
No.
Initial
Value
Comments
Motor Protection Time
Constant
n34
8 min
L1-02
1 min
Set L1-02 = n34 / 8.
Drive Cooling Fan
Operation Selection
n35 0
L8-10 0
J7 J1000
n35 Æ 0
L8-10 Æ 0
n35 Æ 1
L8-10 Æ 1
Terminal S1 Function
Selection
— —
H1-01
40
The function of S1 is fixed to Fwd Run in the
J7. The equivalent setting in the J1000 is
H1-01 = 40 (default).
Terminal S2 Function
Selection
n36 2
H1-02
41
Terminal S3 Function
Selection
n37 5
H1-03
24
Terminal S4 Function
Selection
n38 3
H1-04
14
J7 J1000
n36 ~ 39 Æ 2
H1-02 ~ 05 Æ 41
n36 ~ 39 Æ 3
H1-02 ~ 05 Æ 24
n36 ~ 39 Æ 4
H1-02 ~ 05 Æ 25
n36 ~ 39 Æ 5
H1-02 ~ 05 Æ 14
n36 ~ 39 Æ 6
H1-02 ~ 05 Æ 3
n36 ~ 39 Æ 7
H1-02 ~ 05 Æ 4
n36 ~ 39 Æ 8
H1-02 ~ 05 Æ 5
n36 ~ 39 Æ 10
H1-02 ~ 05 Æ 6
n36 ~ 39 Æ 11
H1-02 ~ 05 Æ 7
n36 ~ 39 Æ 12
H1-02 ~ 05 Æ 8
n36 ~ 39 Æ 13
H1-02 ~ 05 Æ 9
n36 ~ 39 Æ 14
H1-02 ~ 05 Æ 61
n36 ~ 39 Æ 15
H1-02 ~ 05 Æ 62
n36 ~ 39 Æ 16
H1-02 ~ 05 Æ A
n36 ~ 39 Æ 17
H1-02 ~ 05 Æ 1
n36 ~ 39 Æ 18
H1-02 ~ 05 Æ 2
n36 ~ 39 Æ 19
n04 Æ 0
H1-02 ~ 05 Æ 28
Set the stop time C1-
09
n36 ~ 39 Æ 19
n04 Æ 1
H1-02 ~ 05 Æ 24
n36 ~ 39 Æ 20
n04 Æ 0
H1-02 ~ 05 Æ 15
Set stop time C1-09,
no alarm message
.
n36 ~ 39 Æ 20
n04 Æ 1
Can not be set.
n36 ~ 39 Æ 21
n04 Æ 0
H1-02 ~ 05 Æ 29
Set the stop time
C1-09
n36 ~ 39 Æ 21
n04 Æ 1
H1-02 ~ 05 Æ 25
n36 ~ 39 Æ 22
n04 Æ 0
H1-02 ~ 05 Æ 17
Set stop time C1-09,
no alarm message
.
n36 ~ 39 Æ 22
n04 Æ 1
Can not be set.