beautypg.com

Yaskawa J7 to J1000 User Manual

Page 15

background image

(Header Title) Application Note


Doc#: PL.J1000.01 Copyright Yaskawa Electric America, Inc.©2008 www.yaskawa.com August 1, 2008 15 of 19

Subject: Transition Guide

Product: J1000

Document: PL.J1000.01

Title: Product Transition Guide – J7 to J1000

Product Transition Guide – J7 to J1000

J7

J1000

Drive

Function
/ Parameter

Parameter

No.

Initial

Value

Parameter

No.

Initial

Value

Comments

Terminal S5 Function
Selection

n39 6

H1-05 3

J7 J1000

n37 Æ 0

H1-03 Æ 0

n39 Æ 34

H1-04 Æ 10

H1-05 Æ 11

(b1-01 must be set to
0 or 1 and b1-02 must
be set to 1)

n39 Æ 35

H1-05 Æ 67

Terminal MA, MB, MC
Function Selection

n40 1

H2-01 E

J7 J1000

n40 Æ 0

H2-01 Æ E

n40 Æ 1

H2-01 Æ 0

n40 Æ 2

H2-01 Æ 2

n40 Æ 3

H2-01 Æ 1

n40 Æ 4

H2-01 Æ 5

n40 Æ 5

H2-01 Æ 4

n40 Æ 6

H2-01 Æ B

n40 Æ 7

H2-01 Æ 17

n40 Æ 10

H2-01 Æ 10

n40 Æ 11

H2-01 Æ 8

n40 Æ 12

H2-01 Æ 3C

n40 Æ 13

H2-01 Æ 6

n40 Æ 14

H2-01 Æ 1E

n40 Æ 15

H2-01 Æ 7

n40 Æ 16

H2-01 Æ 1A

n40 Æ 17

H2-01 Æ 3D

n40 Æ 18

F (Through Mode)

Analog Input FR
(A1) Gain

n41 100%

H3-03 100%

Analog Input FR (A2)
Bias

n42 0%

H3-04 0%

Analog Input Filter Time
Constant

n43

0.10 s

H3-13

0.03 s

Analog Output AM
Function Selection

n44 0

H4-01

102

J7 J1000

n44 Æ 0

H4-01 Æ 102

n44 Æ 1

H4-01 Æ 103

Analog Output AM Gain

n45 1.00

H4-02

100.0%

Set H4-02 = n45* 100