Yaskawa J7 to J1000 User Manual
Page 15

(Header Title) Application Note
Doc#: PL.J1000.01 Copyright Yaskawa Electric America, Inc.©2008 www.yaskawa.com August 1, 2008 15 of 19
Subject: Transition Guide
Product: J1000
Document: PL.J1000.01
Title: Product Transition Guide – J7 to J1000
Product Transition Guide – J7 to J1000
J7
J1000
Drive
Function
/ Parameter
Parameter
No.
Initial
Value
Parameter
No.
Initial
Value
Comments
Terminal S5 Function
Selection
n39 6
H1-05 3
J7 J1000
n37 Æ 0
H1-03 Æ 0
n39 Æ 34
H1-04 Æ 10
H1-05 Æ 11
(b1-01 must be set to
0 or 1 and b1-02 must
be set to 1)
n39 Æ 35
H1-05 Æ 67
Terminal MA, MB, MC
Function Selection
n40 1
H2-01 E
J7 J1000
n40 Æ 0
H2-01 Æ E
n40 Æ 1
H2-01 Æ 0
n40 Æ 2
H2-01 Æ 2
n40 Æ 3
H2-01 Æ 1
n40 Æ 4
H2-01 Æ 5
n40 Æ 5
H2-01 Æ 4
n40 Æ 6
H2-01 Æ B
n40 Æ 7
H2-01 Æ 17
n40 Æ 10
H2-01 Æ 10
n40 Æ 11
H2-01 Æ 8
n40 Æ 12
H2-01 Æ 3C
n40 Æ 13
H2-01 Æ 6
n40 Æ 14
H2-01 Æ 1E
n40 Æ 15
H2-01 Æ 7
n40 Æ 16
H2-01 Æ 1A
n40 Æ 17
H2-01 Æ 3D
n40 Æ 18
F (Through Mode)
Analog Input FR
(A1) Gain
n41 100%
H3-03 100%
—
Analog Input FR (A2)
Bias
n42 0%
H3-04 0%
—
Analog Input Filter Time
Constant
n43
0.10 s
H3-13
0.03 s
—
Analog Output AM
Function Selection
n44 0
H4-01
102
J7 J1000
n44 Æ 0
H4-01 Æ 102
n44 Æ 1
H4-01 Æ 103
Analog Output AM Gain
n45 1.00
H4-02
100.0%
Set H4-02 = n45* 100