Drive parameter listing (n110-n127) – Yaskawa V74X Drives User Manual
Page 45

Drive Parameter Listing
(n110-n127)
Section 8
PARA-
SETTING RANGE
SETTING
FACTORY
USER
PARA.
METER
NAME
(AND UNITS)
INCREMENT
SETTING
SETTING
REF.
0.1 (sec)
0.1 (sec)
0.1
n110
Motor No-load Current
0 to 99
1 (%)
(Note 1)
2.2
n111
Slip Compensation Gain (Note 4) 0.0 to 2.5
(Note 2)
n112
Slip Compensation Primary
0.0 to 25.5
(Note 2)
5.22
Delay Time
n113
Slip Compensation Selection
0:
Disabled
1
0
During Regeneration
1:
Enabled
0:
Disabled
n115
Stall Prevention Above Base
(level is based on setting of n094)
Speed During Run
1:
Enabled
1
0
(level at Fmax is n094 x 0.4)
0:
Follows acc/dec #1 (n019, n020)
5.23
or acc/dec #2 (n021, n022)
n116
Stall Prevention During Run,
Note: Multi-Function input selectable
1
0
Accel/Decel Time Select
1:
Follows acc/dec #2 (n021, n022)
always
0:
Undertorque detection disabled
1:
Detected during constant speed running.
Operation continues after detection
n117
Undertorque Detection
2:
Detected during constant speed running.
1
0
Select (UL3)
Operation stops during detection
3:
Detected during all frequency conditions.
Operation continues
4:
Detected during all frequency conditions.
coast to stop
5.34
0 to 200%
n118
Undertorque Detection
Inverter rated current = 100%; if n097 = 0
1(%)
0
Level (UL3)
(detection by torque); motor rated torque
becomes 100%
n119
Undertorque Detection
Time (UL3)
0.1 to 10.0
.1
n120
Frequency Reference 9 (Note 4)
0.00
n121
Frequency Reference 10 (Note 4)
0.01 (Hz)
0.00
n122
Frequency Reference 11 (Note 4)
(< 100 Hz)
0.00
n123
Frequency Reference 12 (Note 4) 0.00 to 400.00
or
0.00
5.11
n124
Frequency Reference 13 (Note 4)
0.1 (Hz)
0.00
n125
Frequency Reference 14 (Note 4)
(>= 100 Hz)
0.00
n126
Frequency Reference 15 (Note 4)
0.00
n127
Frequency Reference 16 (Note 4)
0.00
Drive Parameters - Continued
45
IG.V7.01_new format.qxd:IG.V7.01_new format.qxd 8/21/07 2:24 PM Page 45