6.0 New Alarm and Fault Codes

Alarm Display

Name

Description

Corrective Action

FOL_ALM

Following Alarm

Following Alarm

The position error between
the master and slave
exceeded the allowable
amount. (P1-07 – P1-08)

Check for physical obstruction of
slave motion.

Fault Display

Name

Description

Corrective Action

FOL_FLT

Following Fault

Following Error

The position error between
the master and slave
exceeded the allowable
amount. (P1-07 – P1-08)

Check for physical obstruction of
slave motion.

Fault Display

Name

Description

Corrective Action

ALIGN_FLT

Align Fault

Alignment Error

The error count between
the master and slave
exceeded the allowable
amount. (P1-03)

Check the trigger input switches.