beautypg.com

Yaskawa E7 Drive Technical Manual User Manual

Page 8

background image

Date: 02/25/2010, Rev: 10-02

Page 8 of 34

TM.F7SW.064

4.1 Parameters (continued)

Control Mode *1

Para

meter

Numb

er

Modbus

Address

Parameter Name

Digital Operator

Display

Description

Range

Default

Cha
nge Duri

ng

Run

V/f

V/f w/

PG

Open Loop

Vector

Flux Vector

P1-10 609H

Position Units

Selection

Position Units

Selects the units used for the

follower drive Position Error

Monitor (U1-96).

0: Encoder Counts

Position error is displayed in

quadrature follower encoder

counts (cts).

1: Motor Revs

Position error is displayed in

follower motor revolutions

(0.001rev).

2: Motor Degrees

Position error is displayed in

follower motor degrees

(0.1°).

3: Motor Radians

Position error is displayed in

follower motor radians

(0.001rad).

Note: ELS modes only.

0 ~ 3

0

Yes A A

A

A

P2-01 60AH

Digital Ratio

Adjustment

Digital RatioAdj

Sets the digital gear ratio

adjustment of the follower

drive. The gear ratio

adjustment is also influenced

by the analog, MOP and

communication gear ratio

adjustments.

-99.99

~

+99.99

%

0.00 Yes A A A A

P2-02 60BH

MOP Adjust Time

MOP Adjust

Time

Sets the time for the MOP ratio

adjustment to change by

100.00% when the MOP

Adjust Increase or MOP Adjust

Decrease multi-function input

is closed.

0.0 ~

6000.0

sec

50.0 Yes A A A A

P2-03 60CH

Gear Ratio

Adjustment Ramp

Time

Ratio Adj Ramp

Sets the time for the composite

gear ratio adjustment of the

follower drive to change by

100.00%.

0.0 ~

6000.0

sec

10.0 Yes A A A A

*1: Access Level (A1-01): Q = “Quick Start”, A = “Advanced”, F = “Factory”.