4.4 Multi-function Digital Output Settings (H2-0X)

Control Mode *1

Setting

Name

Description

V/f

V/f w/

PG

Open Loop

Vector

Flux Vector

40

Follower Position Deviation

Closed: The position error has exceeded the Follower Deviation Level

(P2-06).

Note: ELS modes only.

41

Align Complete

– Closed after a successful alignment operation

completes. Opens when the follower is stopped, faulted, or electronic line

shaft position error is cleared or disabled. Also opens when an

advance/retard command is given.

42

In Alignment

– Closed after both trigger inputs are received AND the

distance between them is less than the P4-04 value.

Open after:

• The first trigger has been received, and the accumulated

distance exceeds the sum of the |P4-03| and P4-04

distances.

• When the follower is stopped, faulted, or electronic line

shaft position error is cleared or disabled.

• An

advance/retard

command

is

given.

*1: = Available, – = Not Available.


4.5 Multi-function Analog Input Settings (H3-0X)

Control Mode *1

Setting

Name

Description

Scaling

V/f

V/f w/

PG

Open Loop

Vector

Flux Vector

20

Analog Ratio Adjustment

Input value is added to the digital, MOP and

network communication ratio adjustment to form

the total gear ratio adjustment.

100%

=

100.00%

*1: = Available, – = Not Available.