Yaskawa E7 Drive Technical Manual User Manual
Page 17

Date: 02/25/2010, Rev: 10-02
Page 17 of 34
TM.F7SW.064
4.4 Multi-function Digital Output Settings (H2-0X)
Control Mode *1
Setting
Name
Description
V/f
V/f w/
PG
Open Loop
Vector
Flux Vector
40
Follower Position Deviation
Closed: The position error has exceeded the Follower Deviation Level
(P2-06).
Note: ELS modes only.
41
Align Complete
– Closed after a successful alignment operation
completes. Opens when the follower is stopped, faulted, or electronic line
shaft position error is cleared or disabled. Also opens when an
advance/retard command is given.
42
In Alignment
– Closed after both trigger inputs are received AND the
distance between them is less than the P4-04 value.
Open after:
• The first trigger has been received, and the accumulated
distance exceeds the sum of the |P4-03| and P4-04
distances.
• When the follower is stopped, faulted, or electronic line
shaft position error is cleared or disabled.
• An
advance/retard
command
is
given.
*1: = Available, – = Not Available.
4.5 Multi-function Analog Input Settings (H3-0X)
Control Mode *1
Setting
Name
Description
Scaling
V/f
V/f w/
PG
Open Loop
Vector
Flux Vector
20
Analog Ratio Adjustment
Input value is added to the digital, MOP and
network communication ratio adjustment to form
the total gear ratio adjustment.
100%
=
100.00%