13 Installation Conditions of EMC Directive

E-27

SGDS-15A1†A to -50A1†A: Three-phase 200 VAC, 1.5 kW to 5.0 kW

U, V, W

L1, L2, L3

L1C, L2C

CN2

CN6

PE

PE

1

2

3

4

Clamp

Clamp

Clamp

Power supply
Three-phase 200 VAC

SERVOPACK

Encoder

Servo-

motor

Brake

Noise

filter

Brake power supply

Surge

absorber

Ground plate

Core

Host controller

The cable must be
coiled four times.

Symbol

Cable Name

Specification

c

Serial communication cable

Shield cable

d

Servomotor cable

Shield cable

e

Encoder cable

Shield cable

f

AC Line cable

Shield cable