beautypg.com

12 general specifications – Yaskawa Σ-III Series User Manual

Page 21

background image

12 General Specifications

E-19

12 General Specifications

The following table shows the SERVOPACK general specifications.

Item

Specifications

Operating/Storage Temperature

0 to +55

°C/-20 to +85 °C

Operating/Storage Humidity

90 %RH or less (non-condensing)

Operating Environment

Installation category (Overvoltage category): III
Pollution degree: 2
Protection class: 10
Altitude: 1,000 m max.

Vibration Resistance

4.9 m/s

2

Shock Resistance

19.6 m/s

2

Voltage Resistance

Voltage: 1,500 V rms AC, for one minute
Braking current: 30 mA
Frequency: 50 Hz or 60 Hz
Voltage applied points: Between the frame ground and the
point where the terminals L1, L2, L3, L1C, L2C, U, V, and W
connect.

Insulation Resistance

10 M

Ω

min. (500 VDC megger) between the frame ground

and the power terminals U, V, and W

Overseas Standards

UL Standards: UL508C
EMC Directives: EN61000-6-2, EN55011 (group1 class A)
Low Voltage Directive: EN50178

This manual is related to the following products: