Three-phase 200 v – Yaskawa Σ-III Series User Manual

Page 18

background image

E-16

„

Three-phase 200 V

* 1. These circuits are power lines, separated by the protecting separator.

Do not touch these terminals when the power is ON to avoid electric
shock.

* 2. These circuits are SELV circuits and are separated from all other cir-

cuits by double and reinforced insulation. The CN1 input signal is
available for sink or source circuits.

* 3. A SERVOPACK with a capacity of 6.0 kW or more has both the B1

terminal and the terminal.

* 4. SERVOPACKs with a capacity of 6.0 kW or more do not have a B3

terminal.

* 5. SERVOPACKs with a capacity of 6.0 kW or more do not have termi-

nals 1 and 2. Use terminal instead.

Note: Customers must purchase a 24-VDC power supply with a double-

shielded enclosure.

1SA

L1

L1C

PG

SERVOPACK

SGDS-

A

U

V

W

M

0 V

24

1Ry

ALM+

ALM

1D

1KM

1Ry

1KM

1Ry

1KM

L2
L3

B2
B3

L2C

CN1

CN2

1QF

R

S

T

1PL

FIL

+24V

∗2

∗1

B1/

1

2

Other
connectors

(For servo

alarm display)

Main circuit
power supply

ON

OFF

Main circuit
power supply

: Indicator lamp
: Surge absorber
: Flywheel diode

1PL
1SA
1D

1QF
FIL
1KM

1Ry

: Molded-case circuit breaker
: Noise filter
: Magnetic contactor

: Relay

∗3

∗4

∗5