E-14

„

Ground Terminal

„

Signal Line Wire Sizes

Following table shows appropriate cables for CN1 and CN2 SERVOPACK connectors.

Wire sizes were selected for three cables per bundle at 40

°

C surrounding air temperature

with the rated current.

Main

Circuit
Power

Supply

Capacity

(kW)

SERVOPACK

Model

Ground Terminal

SGDS-

Wire Size

(mm

2

)

Terminal

Screw

Size

Tightening

Torque

(N

‚

m)

Single-

phase

100 V

0.05

A5F

HIV2.0 or

more

M4

1.2 to 1.4

0.1

01F

0.2

02F

Single-

phase

200 V

0.05

A5A

HIV2.0 or

more

M4

1.2 to 1.4

0.1

01A

0.2

02A

0.4

04A

0.75

08A

Three-

phase

200 V

0.45

05A

HIV2.0 or

more

M4

1.2 to 1.4

1.0

10A

1.5

15A

2.0

20A

3.0

30A

5.0

50A

6.0

60A

M6

2.5 to 3.8

7.5

75A

Connector Name and

Signal

Item

Specification

Control I/O
Signal
Connector

CN1

Cable

Use twisted-pair or shielded twisted-pair wire.

Applicable wire

AWG24 (0.2 mm

2

), AWG26 (0.12 mm

2

),

AWG28 (0.08 mm

2

), AWG30 (0.05 mm

2

)

Finished cable
dimension

φ16.0 mm (φ0.63 in) MAX.

PG Signal
Connector

CN2

Cable

Use Yaskawa cable, or shielded twisted-pair
wire if Yaskawa cable is not used.

Applicable wire

AWG24 (0.2 mm

2

), AWG26 (0.12 mm

2

),

AWG28 (0.08 mm

2

), AWG30 (0.05 mm

2

)

Use AWG22 (0.33 mm

2

) for the encoder power

supply and AWG26 (0.12 mm

2

) for other sig-

nals. These conditions permit wiring distances
up to 20 m (65.6 ft).

Finished cable
dimension

φ6.8 mm (φ0.27 in) MAX.