beautypg.com

4 typical main circuit wiring examples – Yaskawa Σ-III Series User Manual

Page 17

background image

10 Wiring

E-15

10.4 Typical Main Circuit Wiring Examples

Only qualified personnel should perform the wiring. Design the circuit so that the main cir-
cuit power supply turns OFF at emergency stop.

„

Single-phase, 100/200 V

* 1. These circuits are power lines, separated by the protecting separator.

Do not touch these terminals when the power is ON to avoid electric
shock.

* 2. These circuits are SELV circuits and are separated from all other cir-

cuits by double and reinforced insulation. The CN1 input signal is
available for sink or source circuits.

Note: Customers must purchase a 24-VDC power supply with a double-

shielded enclosure.

L1

L1C

SERVOPACK

SGDS-

F

SGDS-

A

U

V

∗1

∗2

W

M

PG

ALM

0 V

24

1Ry

ALM+

1D

1KM

1Ry

1KM

1SA

1Ry

1KM

L2

B2

L2C

CN2

CN1

1QF

R

T

1PL

FIL

+24V

1

2

B1/

Other
connectors

(For servo

alarm display)

Main circuit
power supply

ON

OFF

Main circuit
power supply

: Indicator lamp
: Surge absorber
: Flywheel diode

1PL
1SA
1D

1QF
FIL
1KM

1Ry

: Molded-case circuit breaker
: Noise filter
: Magnetic contactor

: Relay

This manual is related to the following products: