10 wiring, 1 molded-case circuit breaker and fuse capacity, 2 main circuit wiring – Yaskawa Σ-III Series User Manual
Page 13

10 Wiring
E-11
10 Wiring
10.1 Molded-case Circuit Breaker and Fuse Capacity
* 1. Nominal value at the rated load. The specified derating is required to select an appropriate
fuse capacity.
* 2. Cutoff characteristics (25
°
C): 200% two seconds min. and 700% 0.01 seconds min.
Note: 1. Do not use a fast-acting fuse. Because the SERVOPACK’s power supply is a capacitor
input type, a fast-acting fuse may blow when the power is turned ON.
2. The SGDS SERVOPACK does not include a protective grounding circuit. Install a
ground-fault protector to protect the system against overload and short-circuit or protec-
tive grounding combined with the molded-case circuit breaker.
10.2 Main Circuit Wiring
SGDS SERVOPACKs are suitable under the following conditions.
• With 100 V class: Less than 5000 Arms,120 V maximum.
• With 200 V class: Less than 5000 Arms, 240 V maximum.
SERVOPACKs must be used with UL-listed fuses or circuit breakers, in accordance with the
National Electrical Code (NEC).
Use 75
°C heat-resistant copper wires or an equivalent.
Main Circuit
Power Supply
SERVOPACK Model
Power Supply
Capacity per
SERVOPACK
(kVA)
Current Capacity of the
Molded-case Circuit Breaker
and the Fuse
(A
rms
)
∗
1,
∗
2
Rated Voltage
Capacity
(kW)
SGDS-
Fuse
MCCB
Single-phase
100 V
0.03
A3B
0.25
4
250 V
240 V
0.05
A5F
0.25
0.10
01F
0.40
0.20
02F
0.60
6
0.40
04F
1.2
12
Single-phase
200 V
0.05
A5A
0.25
4
0.10
01A
0.40
0.20
02A
0.75
0.40
04A
1.2
8
0.80
08A
2.2
16
Three-phase
200 V
0.45
05A
1.4
4
1.0
10A
2.3
7
1.5
15A
3.2
10
2.0
20A
4.3
13
3.0
30A
5.9
17
5.0
50A
7.5
28
6.0
60A
12.5
32
7.5
75A
15.5
41