Figure 23, 10 troubleshooting – Yaskawa PROFINET User Manual
Page 54

10 Troubleshooting
54
YASKAWA SIEP YEACOM 07A 1000-Series Option PROFINET SI-EP3 Technical Manual
Figure 23
Figure 24 bUS Error Delay Timing Example
Related Parameters
Table 31 Parameters related to bUS Error Auto-Reset Functionality
No.
(Addr. Hex)
<2> If F6-01 is set to 3, then the drive will continue to operate when a bUS error is detected. Use caution and proper safety measures, when installing
an emergency stop switch.
<5> The availability of this feature/function depends on drive model, software version and Profinet firmware version. Refer to
for specifics
relating to your drive.
Name
Description
Default
F6-01
(03A2)
Operation Selection after
Communications Error
Determines drive response when a bUS error is detected during
communications with the option.
0: Ramp to Stop
1: Coast to Stop
2: Fast-Stop
3: Alarm Only
4: Alarm (d1-04)
5: Alarm Ramp to Stop
1
F6-14
(03BB)
bUS Error Auto Reset
0: Disabled
1: Enabled
0
F7-16
(03F4)
Communication Loss Timeout
Sets the timeout value for communication loss detection in tenths of
a second.
A value of 0 disables the connection timeout.
Example: An entered value of 100 represents 10.0 seconds.
Note: A change to this parameter setting is not effective until main
power to the drive is cycled.
0.0