8 Communication
YASKAWA ELECTRIC
SIEP C730600 69A 1000-Series Option SI-EP3 Technical Manual
33
Table 21 PROFIdrive Response Header
Table 22 Data Types for Format Field
Table 23 PROFIdrive Parameter Request Error Codes
Field(s)
Description
Range
Response Reference Mirrored from the request.
1 to 255
Response ID
Response from the slave. In the event that requested services fail, a
“not acknowledged” (NAK) response will be indicated.
Request Param OK (0x01) Request Param NAK
(0x81) Change Param OK (0x02) Change Param NAK
(0x82)
DO-ID
To be set to 1.
0 to 255
No. of Parameters
<1> Only when Request ID is 0x01 (Request Parameter OK). The Format, Number of Values, and Value Fields are repeated for other parameters.
Number of parameters that are present in the response.
1 to 37
Format
Refer to
for details.
–
Number of Values
Number of values following.
0 to 234
Values
The values of the request.
When there is an odd number of bytes, a zero byte is appended to
ensure the word structure of the telegram.
Varies based on value
Code
Type
0x00 (Reserved)
0x01 to 0x36
Standard data types
0x37 to 0x3F
(Reserved)
0x40 Zero
0x41 Byte
0x42 Word
0x43 Double
word
0x44 Error
0x45 to 0xFF
(Reserved)
Error #
Meaning
Used at
0x00 Impermissible
parameter
number
Access to unavailable parameter.
0x01
Parameter value cannot be changed
Change access to a parameter value that cannot be changed.
0x02
Low or high limit exceeded
Change access with value outside the limits.
0x03 Invalid
subindex
Access
to unavailable subindex.
0x04
No array
Access with subindex to non-indexed parameter.
0x05
Incorrect data type
Change access with value that does not match the data type of the parameter.
0x06
Setting not permitted (can only be reset)
Change access with value unequal to 0 when this is not permitted.
0x07 Description
element
cannot be changed
Change access to a description element that cannot be changed.
0x09
No description data available
Access to unavailable description (parameter value is available).
0x0B
No operation priority
Change access rights without rights to change parameters.
0x0F
No text array available
Access to text array that is not available (parameter value is available).
0x11
Request cannot be executed because of
operating mode
Access is temporarily not possible for reasons outside scope of these instructions.
0x14 Value
impermissible
Change access with a value that is within limits but is not permissible for other long-
term reasons (parameter with defined single values).
0x15
Response too long
The length of the current response exceeds the maximum transmittable length.
0x16
Parameter address impermissible
Illegal value or value that is not supported for the attribute, number of elements,
parameter number or sub-index, or a combination.
0x17 Illegal
format
Write
request: Illegal format or format of parameter data that is not supported.
0x18
Number of values inconsistent
Write request: Number of values of parameter data does not match number of elements
at the parameter address.
0x19
DO nonexistent
Request to DO, which does not exist.
0x65 to 0xFF Manufacturer-specific
–
0x65 Vendor-specific
error
Vendor-specific error.
0x66
Request not supported
Request not supported.
0x67 Communication
error
Request cannot be completed because of communication error.
0x6F
Time-out error
Request aborted due to time-out.