8 Troubleshooting

YASKAWA ELECTRIC TOBP C730600 42C 1000-Series Option SI-P3 Installation Manual

31

Digital Operator Display

Fault Name

oFA00

Non-Compatible Option connected to drive port CN5-A

Option is not properly connected.

Cause

Possible Solution

Non-compatible option
connected to drive port CN5-A

Use only compatible options. Connect the SI-P3 to CN5-A. For other option
connections, refer to the Installation Manual for those options.

Digital Operator Display

Fault Name

oFA01

Option Fault (CN5-A)

Option is not properly connected.

Cause

Possible Solution

Problem with the connector
between the drive and option.

Turn the power off and check the connectors between the drive and option.

Digital Operator Display

Fault Name

to

oFA30 to

oFA43

Option Fault (CN5-A)

Communication ID error.

Cause

Possible Solution

Option hardware fault.

Replace the option. Contact Yaskawa for assistance.

Digital Operator Display

Fault Name

oFb00

Non-Compatible Option connected to drive port CN5-B
Non-compatible option is connected.

Cause

Possible Solution

Non-compatible option
connected to drive port CN5-B.

Use only compatible options. Connect the SI-P3 to CN5-A. For other option
connections, refer to the Installation Manual for those options.

Digital Operator Display

Fault Name

oFb02

Option Fault (CN5-B)
Two of the same option are connected simultaneously.

Cause

Possible Solution

Options AI-A3 or D1-A3
connected to the CN5-B port
while an option was connected
to CN5-A.

Only one of these options, AI-A3, DI-A3 or SI-†† option can be connected to the
drive at the same time. The SI-N3 must be connected to CN5-A.

Digital Operator Display

Fault Name

oFc00

Non-Compatible Option connected to drive port CN5-C
Non-compatible option is connected.

Cause

Possible Solution

Non-compatible option
connected to drive port CN5-C.

Use only compatible options. Connect the SI-P3 to CN5-A. For other option
connections, refer to the Installation Manual for those options.