5 Installation Procedure

20

YASKAWA ELECTRIC

TOBP C730600 50C YASKAWA 1000-Series Option SI-T3 Installation Manual

5.

Route the option wiring.

Depending on the unit model, some unit may require routing the wiring through the

side of the front cover to the outside to provide adequate space for the wiring. Refer

to the Peripheral Devices & Options section of the unit instruction manual for more

information on wire routing of specific models.

Route the wiring through the side of the front cover to the outside. In these cases,

using diagonal cutting pliers, cut out the perforated openings on the left side of the

unit front cover as shown in

Figure 8

-A. Sharp edges along the cut out should be

smoothed down with a file or sand paper to prevent any damage to the wires.

Route the wiring inside the enclosure as shown in

Figure 8

-B for units that do not

require routing through the front cover.

Note: 1. Separate communication cables from main circuit wiring and other electrical lines.

2. Connect the terminator (model No.: JEPMC-W6022-E) to the option modular connector (CN3) on the

end unit of the communication lines.

Figure 8

Figure 8 Wire Routing Examples

B

A