beautypg.com

SMA WB 5000 Installation User Manual

Page 29

background image

SMA

Technology AG

Installation

Installation Guide

WB50_60-11:SE4005

Page 29

Connecting the AC output

To connect the AC output, proceed as follows:

1.

Check the grid voltage. If this is higher than 260
V, the Windy Boy 5000 / 6000 will not be fully
operational. In this case, contact the local grid
operator for assistance.

Max. 260V!

The maximum grid voltage for feeding

electricity into the grid is 260 V!

2.

Isolate the grid connection (switch the line circuit
breaker to its "off" position), make sure it cannot
be switched back on, and test to make sure no
voltage is present.

You must make sure that no voltage is

present at the AC output before opening

the Windy Boy!

3.

Remove the screws that secure the case of the
Windy Boy 5000 / 6000 and remove the cover.

4.

Connect the earth wire (PE) of the mains cable
to the left terminal of the right terminal block
(see the figure on the right).

PE conductor connection

1.

2.

3.

Off!

Netzw

echselr

ichter fü

r Wind

energie

anlage

n

Grid tie

d inver

ter for w

ind turb

ines

Pac

903W

Upv

330V

Windy

Boy

N

L1

230 Vac:

PE

This manual is related to the following products: