4 stand-alone mains grid, Stand-alone mains grid – SMA WB 5000 Installation User Manual
Page 25
SMA
Technology AG
Installation requirements
Installation Guide
WB50_60-11:SE4005
Page 25
The power read on the X axis is approx. 6.2 kW per phase.
Consequently, there should be installed only one Windy Boy 5000 / 6000 per phase
in this example. A higher output per phase, without causing a switch-off because of
AC overvoltage, requires better connection conditions for the Windy Boy 5000 /
6000 (e.g. a cable with a larger diameter).
4.4 Stand-alone mains grid
When providing electricity using Sunny Island systems:
configure the Sunny Boy 3800 according to the Sunny Island instruction
manual.
0
5
10
15
20
25
30
0,5
0,6
0,7
0,8
0,9
1,0
1,1
1,2
1,3
1,4
1,5
230 V
Mains supply impedance [Ohm]
Output [kW] per phase