When choosing the installation site, be sure to note the following:

When choosing the installation site, ensure there is enough space for heat to dissipate.
Under normal conditions, the following guidelines should be applied for the space to
be kept clear around the Sunny Boy SB 1100LV:

In domestic installations, the unit should not be
mounted on plasterboard walls or similar as
otherwise audible vibrations are likely to result.
We recommend securing the unit to a solid surface.
The Sunny Boy makes noises when in use which can,
in the domestic setting, be seen as a nuisance.

Warning! Risk of burns!
The temperature of individual parts of the case and components within the
Sunny Boy can reach more than 60 °C. Touching could result in burns!

Do not install the Sunny Boy on flammable construction materials, in areas
where highly inflammable materials are stored or in potentially explosive
environments!

Minimum clearance

Sides

20 cm

Top

20 cm

Underneath

20 cm

Front

5 cm