beautypg.com

2 connecting consumer loads, Connecting consumer loads – SMA AUTOMATIC SWITCH BOX L User Manual

Page 20

background image

Electrical Connection

SMA Solar Technology AG

20

AS-BoxL-IEN084410

Installation Guide

5.2.2 Connecting Consumer Loads

1. Select a suitable opening for the consumer loads cable and poke a hole through it with a pointy

tool.
The cable has to be tightly enclosed by the opening after it is inserted.

2. Pull the consumer loads cable through the cable opening into the interior of the Automatic

Switch Box.

3. Connect PE and N to the "X3/Backup Loads" connection terminal according to the label. The

second connection terminal "N" is not assigned.

4. Connect L1, L2, and L3 to the "F5 Backup Loads" fuse elements according to the labels.

☑ The consumer loads are connected.