9  Troubleshooting

SMA Solar Technology AG

30

METERBOXSBU-IA-en-40

Installation Manual

9 Troubleshooting

Message

Cause and corrective measures

"RDY" LED is off.

The voltage supply is interrupted or the Meter Box is defective.
Corrective measures:
If you are using a plug-in power supply:

• Ensure that voltage is present at the socket-outlet.
• Use the plug-in power supply included in the delivery.

If you are using the 2-pole plug:

• Check the alternative voltage source (see Section 6.5.2).
• Keep the insulated conductors as short as possible.
• Make sure that the selected conductor cross-section is sufficient.
• Insert the plug-in power supply included in the delivery.

After checking the plug-in power supply or the alternative voltage source,
restart the Meter Box:

1. If you are using a plug-in power supply, pull the plug from the

socket-outlet.

2. If you are using the 2-pole plug, disconnect the voltage source.
3. Wait 10 minutes. This allows the capacitors to discharge.
4. If you are using a plug-in power supply, insert the plug into the

socket-outlet.

5. If you are using the 2-pole plug, start the voltage source.

☑ "RDY" LED lights up green.
✖ "RDY" LED does not light up green?

The Meter Box may be defective.
• Contact the SMA Service Line.

"RDY" LED lights up
green.

The Meter Box is in operation.

LED next to "RDY"
LED is flashing red.

Communication cable route fault.
Corrective measures:

• Ensure that the terminators are attached

(see Section 6.4 "Connecting the Communication", page 24).

• Make sure all RJ45 plugs of the communication terminals are

inserted properly.