10  Troubleshooting

SMA Solar Technology AG

46

PVO-BOX-IA-en-10

Installation Manual

x

x

x

Yellow,
red

x

Insulation fault:

– Insulation resistance (including

inverter) against earth less than
200 kΩ

– Earth fault in the PV array
– Inverter and PV Offset Box in operation

simultaneously

• Check PV array for earth fault

(see inverter installation manual).

x

x

x

x

Yellow,
red

Device fault

• Contact the SMA Service Line

(see Section 14 "Contact", page 52).

Off

Flashing
red

Flashing
red

Flashing
red

x

Setting fault:

– The operating mode and output

voltage settings are not compatible

– Prohibited switch position selected

• Configure the SMA PV Offset Box

correctly (see Section 8 "Commissioning",
page 41).

Off

Off

Off

Off

Off

No supply voltage

• Check AC-side installation.

Description and corrective measure