beautypg.com

5 assembly, 1 selecting the mounting location – SMA PVO-N-20 User Manual

Page 15

background image

SMA Solar Technology AG

5  Assembly

Installation Manual

PVO-BOX-IA-en-10

15

5 Assembly

5.1 Selecting the Mounting Location

Requirements for the mounting location:

☐ The installation site must be freely and safely accessible at all times without the necessity for any

auxiliary equipment (such as scaffolding or lifting platforms). Non-fulfillment of these criteria
may restrict servicing.

☐ The mounting surface must be even. The wall brackets of the SMA PV Offset Box must lie flush

with the mounting surface.

☐ The ambient temperature must be between − 25°C and +60°C.
☐ The LED display of the SMA PV Offset Box must be readable.
☐ The mounting location should be close to the inverter. If the device is mounted on the PV array,

support by SMA Service will not be possible.

Danger to life due to fire or explosion
Despite careful construction, electrical devices can cause fires.

• Do not mount the SMA PV Offset Box on flammable construction materials.
• Do not mount the SMA PV Offset Box in the vicinity of highly flammable materials.
• Do not mount the SMA PV Offset Box in potentially explosive areas.