6  Setting the Operating Mode and Output Voltage

Installation Manual

PVO-BOX-IA-en-10

21

Overview of the Configuration Area

Procedure

1. If the SMA PV Offset Box is already in operation, disconnect it from all voltage sources

(see Section 9).

2. Unscrew all the enclosure lid screws and remove the lid.
3. Set the rotary switch M to the desired operating mode.

4. Set the rotary switch V to the desired output voltage.

Item

Explanation

M

Rotary switch for setting the operating mode

V

Rotary switch for setting the output voltage

Switch position

Operating mode

0

No selection (default setting)

1

Night mode

3

Continuous operation

5

Temporary operation 1

7

Temporary operation 2

Switch position

Output voltage

0

No selection (default setting)

1

400 V

3

550 V

5

700 V

7

1,000 V

9

automatic, 1 string

B