7  Electrical Connection

SMA Solar Technology AG

36

PVO-BOX-IA-en-10

Installation Manual

The following DC connection options are possible (as examples):

Figure 13: DC connection options for a multi-string inverter

Connection Options

Cable Connections

Option

Description

A

Multi-string inverter with no DC input assigned - all operating modes

B

Multi-string inverter with one DC input area completely assigned – all operating modes

C

Multi-string inverter with all DC inputs completely assigned – all operating modes

Connection Description

SUNCLIX

1

PV+ connection cable SMA PV Offset Box to inverter or
Y distribution

2 x positive (+)

2

PV − connection cable SMA PV Offset Box to inverter or
Y distribution

2 x negative ( − )

3

PV+ connection cable PV array to inverter

1 x positive (+)

4

PV − connection cable PV array to inverter

1 x negative ( − )

5

PV+ connection cable Y distribution to inverter

1 x positive (+),
1 x negative ( − )

6

PV − connection cable Y distribution to inverter

1 x negative ( − ),
1 x positive (+)

7

PV+ Y distribution

2 x negative ( − ),
1 x positive (+)