beautypg.com

5 error messages during data transfer, Error messages during data transfer – HEIDENHAIN SHB Data Interfaces for HEIDENHAIN User Manual

Page 89

background image

8 – 90

HEIDENHAIN Service Manual for Data Interfaces

8.1.5 Error messages during data transfer

TRANSFERRED VALUE INCORRECT X

X =

A

Faulty character frame

B

Character overflow

C

Faulty character frame or character

overflow

D

Parity error

E

Faulty character frame or parity error

F

Character overflow or parity error

G

Faulty character frame or character

overflow or parity error

H

Receiving buffer overflow

K

Incorrect ESC sequence (only in "ME" mode)

L

Incorrect ESC sequence (only in "ME" mode)

DATA TRANSFER ERRONEOUS X

X =

A

Faulty character frame

D

Parity error

M

The control has received the character for

"Negative Acknowledgement" (NAK) more

than 3 times

N

The control has transmitted the character for

"Negative Acknowledgement" (NAK) more

than 3 times

P

Timeout ACK/NAK

BAUD RATE NOT POSSIBLE

If both data interfaces (RS 232/RS 422) are active
simultaneously, the baud rate of both data interfaces must

be the same.

INTERFACE ALREADY ASSIGNED

A data interface cannot be used for two operating modes at
a time (e.g. DNC mode and simultaneous programming is not
possible with one data interface).

EXT. IN/OUTPUT NOT READY

- DSR signal missing at the TNC

- Transmission cable defective or incorrect

- Wrong interface assignment

PROGAM INCOMPLETE

Data transfer was aborted before the program was