5 error messages during data transfer, Error messages during data transfer – HEIDENHAIN SHB Data Interfaces for HEIDENHAIN User Manual
Page 89

8 – 90
HEIDENHAIN Service Manual for Data Interfaces
8.1.5 Error messages during data transfer
TRANSFERRED VALUE INCORRECT X
X =
A
Faulty character frame
B
Character overflow
C
Faulty character frame or character
overflow
D
Parity error
E
Faulty character frame or parity error
F
Character overflow or parity error
G
Faulty character frame or character
overflow or parity error
H
Receiving buffer overflow
K
Incorrect ESC sequence (only in "ME" mode)
L
Incorrect ESC sequence (only in "ME" mode)
DATA TRANSFER ERRONEOUS X
X =
A
Faulty character frame
D
Parity error
M
The control has received the character for
"Negative Acknowledgement" (NAK) more
than 3 times
N
The control has transmitted the character for
"Negative Acknowledgement" (NAK) more
than 3 times
P
Timeout ACK/NAK
BAUD RATE NOT POSSIBLE
If both data interfaces (RS 232/RS 422) are active
simultaneously, the baud rate of both data interfaces must
be the same.
INTERFACE ALREADY ASSIGNED
A data interface cannot be used for two operating modes at
a time (e.g. DNC mode and simultaneous programming is not
possible with one data interface).
EXT. IN/OUTPUT NOT READY
- DSR signal missing at the TNC
- Transmission cable defective or incorrect
- Wrong interface assignment
PROGAM INCOMPLETE
Data transfer was aborted before the program was