HEIDENHAIN SHB Data Interfaces for HEIDENHAIN User Manual
Page 45
6 – 46
HEIDENHAIN Service Manual for Data Interfaces
The following escape sequences and ASCII characters must be transferred to the printer for
initialization:
The machine parameters MP 226 (5110.0) to MP 233 (5120.3) are present as 16-bit values and
are output in decimal format. The input value may be between 0 and 65535. These machine
parameters are subdivided into bytes.
The most significant byte from MP 226 (5110.0) and MP 230 (5120.0) defines the number of
bytes the control outputs via RS-232-C.
The entry values 0 to 7 are advisable, as up to 7 bytes can be transferred. The next bytes are
output individually in ascending order.
Example:
The escape sequences stated below are not generally valid; they must be defined individually
for each printer (with the help of the printer manual).
Machine parameter block 1: MP 226 (5110.0) to MP 229 (5110.3)
Output of control characters at the beginning of each graphics
Input values:
MP 226
(5110.0):
1548
MP 227
(5110.1):
3338
MP 228
(5110.2):
6963
MP 229
(5110.3):
18432
Machine parameter block 2: MP 230 (5120.0) to MP 233 (5120.3)