HEIDENHAIN SHB Data Interfaces for HEIDENHAIN User Manual
Page 36

April 2010
5 – 37
1)
The transfer rate must be set to 9600 baud.
2)
Change of directory is not possible.
3)
Machine must support LSV2/DNC operation.
4)
File server (LSV2) as of software versions 280 462 05, 280 470 01, 280 472 01 only
5)
TNC 155B
6)
Via Ethernet as of software 280476-xx
7)
For further information, refer to the respective Technical Manual, User's Manual and Service
Manual.
For internals settings please refer to the User's Manuals and Technical Manuals of the controls
and DROs.
FE 1:
For connection of HEIDENHAIN floppy-disk unit FE 401 B (or floppy-disk unit FE 401, software
230 626 03 and later) or other peripheral units.
Data format and protocol adapted to FE 401/B
Protocol:
Blockwise transfer
Data format:
7 data bits, 1 stop bit, even parity
Baud rate:
110 - 115 200 bauds
(depending on the hardware of the HEIDENHAIN product)
Interface parameters:
Fixed
Transfer stop:
Software handshake with DC3
FE 2:
For connection of the HEIDENHAIN floppy-disk unit FE 401 or other peripheral units.
Data format and protocol adapted to FE 401/B
Protocol:
Blockwise transfer
Data format:
7 data bits, 1 stop bit, even parity
Baud rate:
110 - 115 200 bauds
(depending on the hardware of the HEIDENHAIN product)
Interface parameters:
Fixed
Transfer stop:
Software handshake with DC3
MANUALplus M
7)
x
MANUALplus 3110
7)
x
CNC PILOT 3190
7)
x
CNC PILOT 6xx
7)
x
x
x
x
x
GrindPlusIT
7)
x
x
MillPlus
7)
x
x
MillPlusIT V600
7)
x
x
x
x
x
x
Control model
Operating mode
ME
FE
EXT
LSV2
Screen
dump
Host
operation
DNC
Log