beautypg.com

Electrical, Mechanical, Paper – Epson Sylus Pro 10600 User Manual

Page 2: Environmental, Safety approvals, Ink cartridges, Electrical mechanical paper, Environmental safety approvals ink cartridges

background image

EPSON Stylus Pro 10600

2 - EPSON Stylus Pro 10600

9/02

Electrical

Mechanical

Paper

The allowable paper dimensions are shown below:

Notes:

❏ Poor quality paper may reduce print quality and cause paper jams

and other problems. If you encounter problems, switch to a
higher grade of paper.

❏ Do not use curled, folded, or deckle-edge paper.
❏ Depending on the media, best feed and print quality are

guaranteed on EPSON paper with thicknesses of 3.15 to 4.33 mil
(0.08 to 0.11 mm), 64 to 90 gsm.

❏ For best results, use paper under the following conditions:

Temperature:

59 to 77 °F (15 to 25 °C)

Humidity:

40 to 60% RH

Environmental

Safety Approvals

Ink Cartridges

Specification

120V Model

220

240V Model

Input voltage range

90 to 132V

198 to 264V

Rated frequency range

50 to 60 Hz

Input frequency range

49 to 61 Hz

Rated current

1.4 A

0.7 A

Power consumption

Approx. 131 W (ISO 10561 Letter Pattern)
30 W or less in sleep mode

Dimensions

Width: 73.4 inches (1865 mm)
Depth: 28.0 inches (710 mm)
Height: 48.2 inches (1225 mm)

Weight

284 lb (129 kg) with stand

Roll paper

Cut sheets

Size

8.3 to 44 in. wide
(210 to 1118 mm)

8.5 × 11 in. up to 44 in.
wide

Maximum
external roll
diameter

2 in. core: 4 in. (103 mm)
3 in. core: 6 in. (150 mm)

Thickness

3.15 to 19.7 mil (0.8 to
0.5 mm)

3.15 to 59 mil (0.8 to
1.5 mm)

Temperature

Operation: 50 to 95 °F (10 to 35 °C)
Storage:

4 to 104 °F (

20 to 40 °C)

1 month at 104 °F (40 °C)

Transit

4 to 140 °F (

20 to 60 °C),

stored in shipping container
120 hours at 140 °F (60 °C)

Humidity
(without
condensation)

Operation: 20 to 80% RH
Storage:

20 to 85% RH

Transit

5 to 85% RH (stored in
shipping container)

Safety standards UL 1950, CSA C22.2 No. 950 FDA

EMC

FCC part 15 subpart B, class A,
CSA C108.8 class A

Cartridge life:

Photographic Dye ink
2 years from production date

UltraChrome and Archival ink
2 years from production date if unopened;
within 6 months after opening package, at
77 °F (25 °C)

Temperature:

Storage (uninstalled):

22 to 104 °F (

30 to 40 °C); 1 month at 104

°F (40 °C)

Storage (installed):

4 to 104 °F (

20 to 40 °C); 1 month at 104

°F (40 °C)

Transit

:

22 to 140 °F (

30 to 60 °C); 1 month at 104

°F (40 °C), 120 hours at 140 °F (60 °C)

Freezing:
14 °F (

10 °C); ink thaws and is usable after

at least 3 hours at 77 °F (25 °C)

Capacity

500 ml