beautypg.com

HEIDENHAIN TNC 620 (340 56x-03) Cycle programming User Manual

Page 389

background image

HEIDENHAIN TNC 620

389

16.7 MEA

S

. RECT

AN. INSIDE (Cy

c

le

423, DIN/ISO: G423)

8

Measuring log Q281: Definition of whether the TNC

is to create a measuring log:
0: No measuring log
1: Generate measuring log: the TNC saves the log file
TCHPR423.TXT
by default in the directory TNC:\.
2: Interrupt the program run and display the
measuring log on the screen. Resume program run
with NC Start.

8

PGM stop if tolerance error Q309: Definition of

whether in the event of a violation of tolerance limits
the TNC is to interrupt the program run and output an
error message:
0: Do not interrupt program run, no error message
1: Interrupt program run, output an error message

8

Tool for monitoring Q330: Definition of whether the

TNC is to monitor the tool (see "Tool monitoring" on
page 370). Input range: 0
to 32767.9, alternatively tool
name with max. 16 characters
0: Monitoring not active
>0: Tool number in the tool table TOOL.T

Example: NC blocks

5 TCH PROBE 423 MEAS. RECTAN. INSIDE

Q273=+50

;CENTER IN 1ST AXIS

Q274=+50

;CENTER IN 2ND AXIS

Q282=80

;1ST SIDE LENGTH

Q283=60

;2ND SIDE LENGTH

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+10

;CLEARANCE HEIGHT

Q301=1

;MOVE TO CLEARANCE

Q284=0

;MAX. LIMIT 1ST SIDE

Q285=0

;MIN. LIMIT 1ST SIDE

Q286=0

;MAX. LIMIT 2ND SIDE

Q287=0

;MIN. LIMIT 2ND SIDE

Q279=0

;TOLERANCE 1ST CENTER

Q280=0

;TOLERANCE 2ND CENTER

Q281=1

;MEASURING LOG

Q309=0

;PGM STOP IF ERROR

Q330=0

;TOOL

This manual is related to the following products: