Programming: Tools
5.2 T
ool D
a
ta
Operating the tool management
The tool management can be operated by mouse or with the keys and 
soft keys:
In addition, you can perform the following functions by mouse:
Sorting function
By clicking a column of the table head, you sort the data in 
ascending or descending order (depending on the active setting).
Moving columns
You can arrange the columns in any sequence you want by clicking 
a column of the table head and then moving it with the mouse key 
pressed down. The TNC does not save the current column 
sequence when you exit the tool management (depending on the 
active setting).
Showing additional information in the fillable form view
The TNC displays tool tips when you leave the mouse pointer on an 
active input field for more than a second and when you have set the 
EDIT ON/OFF soft key to ON.
Editing functions for tool management
Soft key
Select beginning of table
Select end of table
Select previous page in table
Select next page in table
Call the fillable form view for the tool or magazine 
pocket highlighted in the table. Alternative 
function: Press the ENT key
Go to the next tab: Tools, Pockets, Tooling list, 
T usage order
Search function (Find): Here you can select the 
column to be searched and the search term via a 
list or by entering it
Show programmed-tools column (if Pockets tab 
is active) 
Define the settings:
SORT COLUMN active:
Click the column header to sort the content of 
the column
MOVE COLUMN active:
The column can be shifted by drag and drop
Reset manual settings (shifted columns) to 
original condition