4 pr ogr am run – HEIDENHAIN 530 (340 49x-07) ISO programming User Manual
Page 543

HEIDENHAIN iTNC 530
543
16.4 Pr
ogr
am Run
U
To go to the first block of the current program to start a block scan,
enter GOTO “0”.
U
To select block scan, press the BLOCK SCAN soft key,
or
U
Start-up at N:
Enter the block number N at which the
block scan should end
U
Program:
Enter the name of the program containing
block N
U
Start-up at P
: Enter the number P at which the block
scan should end if you want to start in a point table
U
Table (PNT)
: Enter the name of the point table in
which the block scan should end
U
Repetitions:
If block N is located in a program section
repeat or in a subprogram that is to be run repeatedly,
enter the number of repetitions to be calculated in the
block scan
U
To start the block scan, press the machine START
button
U
Contour approach (see following section)
Entering a program with the GOTO key
Danger of collision!
If you use the GOTO block number key for going into a
program, neither the TNC nor the PLC will execute any
functions that ensure a safe start.
If you use the GOTO block number key for going into a
subprogram, the TNC will skip the end of the subprogram
(G98 L0)! In such cases you must always use the
mid-program startup function.