e

d functions in 340 49x

-0

1

si

nce the pr

edecessor v

e

rsions 340

422-

xx/340

423-xx

HEIDENHAIN iTNC 530

23

Changed functions in 340 49x-01
since the predecessor versions
340 422-xx/340 423-xx

„

The layouts of the status display and additional status display were
redesigned (see “Status Displays” on page 85).

„

Software 340 490 no longer supports the small resolution in
combination with the BC 120 screen (see “Visual display unit” on
page 79)

„

New key layout of the TE 530 B keyboard unit (see “Operating
panel” on page 81)

„

The entry range for the EULPR precession angle in the PLANE EULER
function was expanded (see “Defining the machining plane with
Euler angles: EULER PLANE” on page 409)

„

The plane vector in the VECTOR PLANE function no longer has to be
entered in standardized form (see “Defining the working plane with
two vectors: VECTOR PLANE” on page 411).

„

Positioning behavior of the CYCL CALL PAT function has been
modified (see User's Manual for Cycles).

„

The tool types available for selection in the tool table were increased
in preparation for future functions.

„

Instead of the last 10, you can now choose from the last 15 selected
files (see “Choosing one of the last files selected” on page 129)