1 gener a l user p a ra met e rs – HEIDENHAIN iTNC 530 (340 49x-01) ISO programming User Manual
Page 527

HEIDENHAIN iTNC 530
527
13.1 Gener
a
l User P
a
ra
met
e
rs
TNC displays, TNC editor
Cycles 17, 18 and 207:
Oriented spindle stop
at beginning of cycle
MP7160
Oriented spindle stop: 0
No oriented spindle stop: 1
Programming station
MP7210
TNC with machine: 0
TNC as programming station with active PLC: 1
TNC as programming station with inactive PLC: 2
Acknowledgment of
power interruption
after switch-on
MP7212
Acknowledge with key: 0
Acknowledge automatically: 1
ISO programming: Set
the block number
increment
MP7220
0 to 150
Disabling the selection
of file types
MP7224.0
All file types selectable via soft key: +0
Disable selection of HEIDENHAIN programs (soft key SHOW .H): +1
Disable selection of ISO programs (soft key SHOW .I): +2
Disable selection of tool tables (soft key SHOW .T): +4
Disable selection of datum tables (soft key SHOW .D): +8
Disable selection of pallet tables (soft key SHOW .P): +16
Disable selection of text files (soft key SHOW .A):+32
Disable selection of point tables (soft key SHOW .PNT): +64
Disabling the editor for
certain file types
Note:
If a particular file type is
inhibited, the TNC will
erase all files of this type.
MP7224.1
Do not disable editor: +0
Disable editor for
HEIDENHAIN programs: +1
ISO programs: +2
Tool tables: +4
Datum tables: +8
Pallet tables: +16
Text files: +32
Point tables: +64
Configure pallet files
MP7226.0
Pallet table inactive: 0
Number of pallets per pallet table: 1 to 255
Configure datum files
MP7226.1
Datum table inactive: 0
Number of datums per datum table: 1 to 255
Program length for
program check
MP7229.0
Blocks 100 to 9999
Program length up to
which FK blocks are
permitted
MP7229.1
Blocks 100 to 9999