9 coor di na te t ra n s for m a ti on cy cle s – HEIDENHAIN iTNC 530 (340 49x-01) ISO programming User Manual
Page 397

HEIDENHAIN iTNC 530
397
8.9
Coor
di
na
te
T
ra
n
s
for
m
a
ti
on Cy
cle
s
Editing a pocket table in a Program Run operating mode
In a program run mode you can select the active datum table. Press 
the DATUM TABLE soft key. You can then use the same editing 
functions as in the Programming and Editing mode of operation.
Transferring the actual values into the datum table
You can enter the current tool position or the last probed position in 
the datum table by pressing the "actual-position-capture" key:
8
Place the text box on the line of the column in which you want to 
enter the position.
8
Select the actual-position-capture function: The TNC
opens a pop-up window that asks whether you want 
to enter the current tool position or the last probed 
values.
8
Select the desired function with the arrow keys and
confirm your selection with the ENT key.
8
To enter the values in all axes, press the ALL VALUES
soft key.
8
To enter the value in the axis where the text box is
located, press the CURRENT VALUE soft key.
Configuring the datum table
In the second and third soft-key rows you can define for each datum 
table the axes for which you wish to set the datums. In the standard 
setting all of the axes are active. If you wish to exclude an axis, set the 
corresponding soft key to OFF. The TNC then deletes that column 
from the datum table.
If you do not wish to define a datum table for an active axis, press the 
NO ENT key. The TNC then enters a dash in that column.
To leave a datum table
Select a different type of file in file management and choose the 
desired file.
Status displays
In the additional status display, the following data from the datum 
table are shown (see “Coordinate transformations” on page 45):
Name and path of the active datum table
Active datum number
Comment from the DOC column of the active datum number
Confirm entered line and go to the beginning of next 
line
Add the entered number of lines (reference points) 
to the end of the table
Select list view (standard) or form view.
Function
Soft key