4 d a tu m set ting without a 3-d t o uc h pr obe – HEIDENHAIN TNC 320 (340 55x-04) ISO programming User Manual
Page 325

HEIDENHAIN TNC 320
325
12.4 D
a
tu
m Set
ting without a 3-D T
o
uc
h Pr
obe
Activating a datum from the preset table in the Manual Operation 
mode
Select the Manual Operation mode
Display the preset table.
Select the datum number you want to activate, or
With the GOTO key, select the datum number that 
you want to activate. Confirm with the ENT key.
Activate the preset
Confirm activation of the datum The TNC sets the 
display and—if defined—the basic rotation
Leave the preset table
Activating the datum from the preset table in an NC program
To activate datums from the preset table during program run, use 
Cycle 247. In Cycle 247 you define the number of the datum that you 
want to activate (see User’s Manual, Cycles, Cycle 247 SET DATUM).
When activating a datum from the preset table, the TNC 
resets the active datum shift, mirroring, rotation and 
scaling factor.
However, a coordinate transformation that was 
programmed in Cycle 19 Tilted Working Plane, or through 
the PLANE function, remains active.