Parameter settings for heidenhain angle encoders – HEIDENHAIN ND 261 v.2 User Manual
Page 9

Parameter Settings for HEIDENHAIN Angle Encoders
/ RPD 486
3 600 one
single
0.01°
10
1
/ ROD 1080
0.005°
20
5
3
0.001°
100
1
3
ROD 250C/ROD 280C
9 000 one
single
0.005°
8
5
3
RON 255C/RON 285C
0.001°
40
1
3
ROD 250C/ROD 280C 18 000 dist.c 1000
0.001°
20
1
3
/ROD 282C
0.000 5°
40
5
4
RON 255C/RON 285C
0.000 1°
200
1
4
/RON 287C
ROD 700C/ROD 780C
RON 705C/RON 785C
RON 706C/RON 786C
RON 905 /
36 000 one
single 0.000 1°
100
1
4
ROD 800C/ROD 880C 36 000 dist.c 1000
0.000 1°
100
1
4
RON 806C/ROD 886C
Example:
Set parameters for any encoder
Angle encoder with line count
s = 18 000
Desired display step
a = 0.001°
Subdivision P36 =
=
=
=
= 360° / s / a = 20
Counting mode P37 = 1 (display counts 1, 2, 3, ....)
Decimal places of a: P38 = 3
Convert decimal degrees to degrees, minutes, seconds
1 degree (1°) = 60 minutes (60'); 1 minute (1') = 60 seconds (60'')
1 second (1'')
≈
0.000278°
Count.
mode
P37
Sub-
division
P36
Decim.
places
P38
P43
Reference
marks
Model
Display
step
11 µA
PP
/ 1 V
PP
Signal
periods per
revolution