List of operating parameters – HEIDENHAIN ND 281 B v.1 User Manual

Page 24

background image

24

Parameter

Settings / Function

P00 CODE

Enter a code number:
9 51 48:

To change the protected
operating parameters

41 52 63: To select the linear or angular

measurement mode

10 52 96: Nonlinear axis error

compensation

24 65 84: To lock the keyboard
66 55 44: To show the software version
24 65 82: Distance-to-go display

P01

Units of measurement

1)

Display in millimeters

MM

Display in inches

INCH

P02 X1/X2

Select an encoder input
Signals at X1

11 µAPP

Signals at X2

1 VPP

P08 DISPL.

Display mode

2)

Decimal Degrees

DEC. DEGREE

Deg., minutes, seconds

DEG.MIN.SEC.

P09 ANGLE

Angle display

2)

+/- 180°

+/- 180 DEG.

+/-

ENDLESS

360°

360 DEG

.

1)

Only in linear measurement mode.

2)

Only in angular measurement mode.

List of Operating Parameters

List of Operating Parameters

Parameter

Settings / Function

P11 SCL

Scaling factor

1)

Scaling factor on

SCALING ON

Scaling factor off

SCALNG. OFF

P12 SCL

Scaling factor

1)

Enter a numerical value
0.100000 < P12 < 9.999999
Default setting: 1.000000

P17 SORT

Sorting and tolerance checking
Sorting and tol. checking ON

SORT ON

Sorting and tol. checking OFF

SORT OFF

P18 L.LIMIT

Lower limit for sorting

P19 U.LIMIT

Upper limit for sorting

P21 SERIES

Display for series of measurements

1)

OFF

MIN MAX ACTL DIFF

P23 DISPL.

Display stop for measured value output
Concurrent display
, no display freeze;
the display value is the current actual
value

DISPL. ACTL.

Frozen display; hold display until next
measured value output

DISPL. HOLD

Frozen/concurrent display; freeze display
as long as Pulse/Contact for measured
value output is present

DISPL. STOP