Parameter settings for heidenhain linear encoders – HEIDENHAIN ND 286 User Manual
Page 9
![background image](https://www.manualsdir.com/files/815456/content/doc009.png)
Parameter Settings for HEIDENHAIN Linear Encoders
Parameter
Meaning
Function / Effect
Setting
External REF
REF over D-sub connection EXT
No REF over EXT connection
First status indicator after MOD is pressed
Mode
START PRINT MIN ACTL MAX DIFF
Fast
Fast external reset/preset
Fast Set
repeated
(setting of P53: )
external
REF mode, datum 2 and
reset/preset
measuring series are not usable
No fast preset
Display step
(unit: P01)
The following settings
apply for mm:
Model
Signal
period
[µm]
Reference
marks
P 43
mm
inches
Subdi-
vision
P32
Count.
mode
P33
Decimal
places
P38
one
single
LIF 121
2
dist. c
5000
0,002
0,001
0,000 5
0,000 1
0,000 05
0,000 02
1
2
4
2
1
5
3
3
4
one
single
0,80,001
0,000 2
0,000 05
0,000 01
0,8
4
1
2
3
4
LIF 171
0,4
dist. c
5000
0,000 2
0,000 1
0,000 01
0,000 005
2
4
2
1
4
4
one
single
8
0,002
0,000 1
4
2
3
LIDA 17x
4
dist. c
2000
0,002
0,001
0,000 1
0,000 05
2
4
2
1
3
3
LIM 172
200
one
single
0,2
0,1
0,05
0,01
0,005
0,002
1
2
4
2
1
5
1
1
2
one
single
4
0,002
0,001
0,000 1
0,000 05
2
4
2
1
3
3
LS 176
LS 476
LS 776
2
dist. c
1000
0,002
0,001
0,000 5
0,000 1
0,000 05
0,000 02
1
2
4
2
1
5
3
3
4
one
single
LS 323
LS 623
20
dist. c
1000
0,02
0,01
0,005
0,001
0,000 5
0,000 2
1
2
4
2
1
5
2
2
3
4
0,002
0,001
0,000 1
0,000 05
2
4
2
1
3
3
LT 171
2
one
single
0,002
0,001
0,000 5
0,000 1
0,000 05
0,000 02
1
2
4
2
1
5
3
3
4
0,4
0,000 2
0,000 1
0,000 01
0,000 005
2
4
2
1
4
4
MT xx71
0,2
one
single
0,000 2
0,000 1
0,000 05
0,000 1
0,000 05
0,000 02
1
2
4
2
1
5
4
4
5
ST 1271
4
none
0,002
0,001
0,000 1
0,000 05
2
4
2
1
3
3
2
0,002
0,001
0,000 5
0,000 1
0,000 05
0,000 02
1
2
4
2
1
5
3
3
4
Example: Set parameters for any encoder; Linear encoder with signal period
s = 4 µm; Desired display step a = 0.001 mm;
Subdivision P32 = 0,001
••••
s / a = 4;
Counting mode P33 = 1 (display counts 1, 2, 3, ...);
Decimal places of a: P38 = 3;
For linear measurement using rotary encoders with square-wave output
signals (e.g. ROD 426) on a ballscrew, calculate the signal period [µm] according
to the following formula:
Signal period [µm] =
Enter the parameters
Subdivision, Counting mode and Decimal places as
for linear encoders.
Screw pitch [mm]
•
1000
Line count