HEIDENHAIN ND 286 User Manual
Page 8

Parameter
Meaning
Function / Effect
Setting
Subdivision of encoder signals
Subdivision 4, 2, 1, 0.8, 0.5, 0.4, 0.2, 0.1
Counting
0 - 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 0
mode
0 - 2 - 4 - 6 - 8 - 0
0 - 5 - 0
External Interpolation of Encoder Signals
1, 5, 10, 20, 50
Places after decimal 1 / 2 / 3 / 4 / 5 (up to 7 with inch display)
Decimal point
Reference
One reference mark
marks
Distance-coded with 500
•
SP
(SP = signal period)
Distance-coded with 1000
•
SP
(e.g. for LS 303 C / LS 603 C)
Distance-coded with 2000
•
SP
Distance-coded with 5000
•
SP
Reference mark
Evaluation
evaluation
No evaluation
Encoder
No monitoring (
Alarm Off)
Encoder
monitoring
Contamination
Frequency
Contamination and frequency
Speed of
Slow
data output
Fast, storage rate: P54
Latch speed
0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 12.8 / 25.6 [µs]
Data output
Data output concurrent (
Actual)
from output
Frozen
signal
Frozen/concurrent
Sign level
Low = Minus (
Sign Low)
High = Minus (
Sign High)
Behavior w/o
Data output always active
latch signal
Output high impedance (
Tristate)
Trigger limit 1
Enter numerical value
Trigger limit 2
Enter numerical value
Value for
Enter numerical value for datum setting via
Preset
datum
switching input or with the ENT key
Display
No zero reset/preset with CL/ENT
reset/preset
Zero reset with CL (
Set Zero),
no preset with ENT
Zero reset with CL and
preset with ENT to value in P79
Display after
message displayed
Message
switch-on
message not displayed
Output of
Error signal sent to data output
error signal
Error signal not sent to data output