Grass Valley PDX 208 User Manual
Page 25

PDX208 to Profile Connections
PDX 208 Instruction Manual
2-9
Connecting Two PDX208s to One 4-Channel Profile
Figure 2-9 shows two PDX208s connected to a 4-channel Profile. If connecting to a
PDR100 Profile, see the configuration stickers below the rear panel slots for the
locations of the Disk Recorder boards. To connect two PDX208s to a 4-channel
Profile, refer to Figure 2-6 and Figure 2-9 and:
1. Connect a SCSI cable from the SCSI A bus on the Master Disk Recorder board
(Slot J9) to one of the SCSI Bus 2 connectors on the first PDX208.
2. Connect a SCSI cable from the second SCSI Bus 2 connector on the first PDX208
to one of the SCSI Bus 1 connectors on the first PDX208.
3. Connect a Terminator to the unused SCSI Bus 1 connector on the first PDX208.
4. Connect a SCSI cable from the SCSI C bus on the Slave Disk Recorder board (Slot
J10) to one of the SCSI Bus 1 connectors on the second PDX208.
5. Connect a SCSI cable from the second SCSI Bus 1 connector on the second
PDX208 to one of the SCSI Bus 2 connectors on the second PDX208.
6. Connect a Terminator to the unused SCSI Bus 2 connector on the second PDX208.
Figure 2-9. Two PRX208s Connections to a 4-channel Profile
The connection shown in Figure 2-9 provides eight 9GB disk drives to the SCSI A
bus and eight 9GB disk drives to the SCSI C bus on the 4-channel PDR200 Profile
(or the SCSI B bus on the 4-channel PDR100 Profile).
J10 J9
9687-5
Terminator
SCSI Cable
First PDX208
Second PDX208
PDR200