beautypg.com

Grass Valley PDX 208 User Manual

Page 25

background image

PDX208 to Profile Connections

PDX 208 Instruction Manual

2-9

Connecting Two PDX208s to One 4-Channel Profile

Figure 2-9 shows two PDX208s connected to a 4-channel Profile. If connecting to a
PDR100 Profile, see the configuration stickers below the rear panel slots for the
locations of the Disk Recorder boards. To connect two PDX208s to a 4-channel
Profile, refer to Figure 2-6 and Figure 2-9 and:

1. Connect a SCSI cable from the SCSI A bus on the Master Disk Recorder board

(Slot J9) to one of the SCSI Bus 2 connectors on the first PDX208.

2. Connect a SCSI cable from the second SCSI Bus 2 connector on the first PDX208

to one of the SCSI Bus 1 connectors on the first PDX208.

3. Connect a Terminator to the unused SCSI Bus 1 connector on the first PDX208.

4. Connect a SCSI cable from the SCSI C bus on the Slave Disk Recorder board (Slot

J10) to one of the SCSI Bus 1 connectors on the second PDX208.

5. Connect a SCSI cable from the second SCSI Bus 1 connector on the second

PDX208 to one of the SCSI Bus 2 connectors on the second PDX208.

6. Connect a Terminator to the unused SCSI Bus 2 connector on the second PDX208.

Figure 2-9. Two PRX208s Connections to a 4-channel Profile

The connection shown in Figure 2-9 provides eight 9GB disk drives to the SCSI A
bus and eight 9GB disk drives to the SCSI C bus on the 4-channel PDR200 Profile
(or the SCSI B bus on the 4-channel PDR100 Profile).

J10 J9

9687-5

Terminator

SCSI Cable

First PDX208

Second PDX208

PDR200