Creating the Disk File System

18GB Disk Drive Upgrade

23

SCSI IDs for systems with only the Master EDR Board installed:

- 8-disk system = A:3:0-A:6:0 and B:3:0-B:6:0

- 7-disk system =A:3:0-A:6:0 and B:3:0-B:5:0

- 6-disk system = A:4:0-A:6:0 and B:3:0-B:5:0

NOTE: The disk size is limited to less than 18GBytes for performance reasons.

6. If any of the disk drive IDs do not appear, shut down the Profile system and

check:

- The installation of the cables inside the chassis and the cable connectors

for bent or broken pins.

- Proper seating of the drives in the SCSI backplane.

- The drive connectors for bent or broken pins.

Refer to Figure 4 to determine the physical location for each SCSI ID.

Figure 4. SCSI ID to Physical Location Map

0563-8

C6

C5

C4

C3

A6

A5

A4

A3

B6

B5

B4

B3

A6

A5

A4

A3

SCSI IDs

Master EDR only

Master & Slave EDR