beautypg.com

Replacing components – England's Stove Works 25PAH User Manual

Page 38

background image

38

IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING

CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.

ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR

DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.

REPLACING COMPONENTS

 

Control Board 

The Control Board (Part # PAH‐CB09) is a digital read‐out board.  This board offers a 

wide variety of settings to operate the unit.  The right side panel should be removed prior to 
removing the control board.  The control board can be removed from the unit by loosening the 
two outside screws and pulling the board back to the inside of the stove.  A 6‐amp “quick‐blow” 
fuse is used on this Control Board. 
NOTE:  The bottom three control buttons are preset at the factory and are not user adjustable.  

See the “Daily Operation” section on page 17 of the manual for more instructions on 
Control Board settings. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recommended Heat Ranges:

Low Burn:

Heat Range setting: 1

Room Air Blower setting: 1

Medium Low:

Heat Range setting: 2 – 3

Room Air Blower setting: *

Medium High:

Heat Range setting: 4 – 8

Room Air Blower setting: *

High Burn:

Heat Range setting: 9

Room Air Blower setting: 9

* NOTE: Blower Speed will automatically be adjusted to the desired Heat Range that you

select.

This manual is related to the following products: