IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
INSTALLATION
Mobile Home Installation
The England’s Stove Works, Inc. outside air kit MUST be used for installation of this unit in a
mobile home. Please see the “Outside Air” section on page 15 for more information
regarding outside air connections.
The outside air inlet must be kept clear of leaves, ice and other debris. Keeping the outside
air inlet free of restriction is crucial to preventing air starvation and smoke spillage.
The pellet stove MUST be secured to the floor of the mobile home using lag bolts and the
holes provided in the bottom of the base for this purpose. Outdoor‐aired space heaters
must be attached to the structure.
The pellet stove MUST be grounded with #8 solid copper grounding wire (or equivalent),
terminated at each end with an NEC approved grounded device.
Carefully follow all clearances listed in the appropriate section of this manual AND follow
the venting manufacturer’s minimum clearance requirements. Similarly, be certain the
venting system used is approved for mobile home use.
Installation must be in accordance with Manufacturers Home & Safety Standard (HUD) CFR
3280, Part 24 as well as any applicable local codes.
Use silicone to create an effective vapor barrier at the location where the chimney or
outside air ducting passes through to the exterior of the structure.
WARNING:
DO NOT INSTALL IN A SLEEPING ROOM.
CAUTION
THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL
AND CEILING/ROOF MUST BE MAINTAINED.
DO NOT CUT THROUGH FLOOR JOISTS, WALL STUDS, CEILING TRUSSES OR ANY
OTHER SUPPORTING MATERIAL WHICH COULD BE DETRIMENTAL TO THE
STRUCTURAL INTEGRITY OF THE HOME.
Joist Shield/Firestop
Mobile Home
Approved Type P or PL
Pellet Vent Pipe
Roof Flashing and
Storm Collar
Chimney Cap/Spark Arrestor
For high altitude installations (above 4,000
ft.), the vent pipe should be increased from
3-inch (3”) to four-inch (4”).