IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING

CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.

ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR

DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.

  

2. Loose exhaust fan set screw. 

2. Check set screw for tightness. 

"E‐1" Code On Control Board  1. Vacuum bypass chip missing. 

1. Contact Technical Support. 

Unit Shuts Down in 15‐20 
minutes with an "E‐2" code 
on control board. 

1. Loose thermal sensor. 

1. Check both sides of thermal 
sensor connection (exhaust 
blower and control board). 

  

2. Control board settings. 

2. Start stove on minimum Heat 
Range 5 to ensure a good fire is 
started. 

  

3. Failure to light pellets. 

3. Check igniter for buildup or 
failure. 

"E‐3" Code on Control Board 
(Overfire) 

1. Convection (Room Air) blower 
failure. 

1. Check convection blower for 
proper function, replace if 
necessary. 

  

2. Partially blocked flue. 

2. Check flue for obstructions. 

  

3. Using fuel other than premium 
wood pellets. 

3. Use ONLY premium wood 
pellets in this stove. 

"E‐4" Code on Control Board 
(Proof of flame lost) 

1. The hopper is empty. 

1. Refill the hopper with pellets 
and restart the stove. 

  

2. The hopper lid was left open 
too long during refueling. 

2. Keep the hopper lid open for 
the shortest interval possible 
when refueling.  The safety switch 
stops the auger when the hopper 
lid is open. 

  

3. Component failure. 

3. An auger motor failure or 
combustion motor failure can 
sometimes results in an "E‐4" 
code. 

  

4. Blower speed is set too high, 
cooling firebox too rapidly. 

4. Operate the stove with the 
blower speed and heat range at 
the same value. 

Notes: 

  

  

  

 

  

1. Whenever instructed to check/replace the vacuum sensor, also check for loose or cracked vacuum 
hose.  Also, be certain the vacuum measurement port in the firebox is kept clean (clean with a pipe 
cleaner or brush, do not use a vacuum to clean). 
  

 

  

2. To restart and clear an error code displayed on the control board, push the "ON" button and the 
unit should reset the error and restart. 
  

 

  

3. If you are uncertain about the meaning of an error code or have any questions at all, PLEASE 
contact Technical Support at (800)245‐6489. 