CONTROL BOARD SETTINGS
The control board on this stove allows the user to adjust the heat output and convection
blower speed, turn the unit on and off, and test components for function (more on diagnostic
mode later).
The lower buttons on the control board (Low Fuel Feed, Low Burn Air, and Air on Temp) are
not meant to be adjusted during normal operation of the unit. These buttons are factory
preset and can not be adjusted by the user.
To energize the unit and initiate a fire, press the “On” button. The LED above the button
should turn green and the control board should display “S U” shortly after pressing the
button.
To shut the unit down, press the “Off” button. The LED above the button should turn red
and the board should display “S d” shortly after pressing the button. This initiates the shut
down sequence, and the stove will remain in shut down mode until it has cooled down.
To increase the heat output of the stove, press the “Up” heat range button. The number in
the heat range display window will increase, signifying that the control board is now
adjusting the heat output to your desired level. The blower speed will increase the same
amount as the heat range, because the stove is designed to operate with the blower speed
greater than or equal to the heat range. Pressing the “Down” arrow will decrease the heat
range and blower speed.
To increase the blower speed without increasing the heat range, press the Blower Speed
“Up” arrow until the desired blower speed is shown in the display window. Pressing the
“Down” arrow will decrease the blower speed; however, the control board will not allow
the blower speed to be set lower than the heat range.
Caution
This unit is meant to operate only with the ash pan and main viewing
door closed. Smoke spillage and an inefficient, lazy burn will result
from attempting to operate the stove with either door open.
In addition, using fuel other than wood pellets can create an unsafe
situation and can also generate excess carbon monoxide. Carbon
monoxide is an odorless, colorless gas which can be deadly.
Please burn only wood pellets.