MONTHLY MAINTENANCE 

Important Notes 

 As with any maintenance concerning this unit, be sure the unit is “OFF,” has completed 

the Shut‐Down cycle, and is completely cool BEFORE beginning. 

 Be aware that metal parts in the firebox can remain HOT long after the fire has gone out 

and EVEN after the Shut‐Down cycle is complete.  Always use extreme caution when 
handling potentially hot stove parts, even if you think they should be cold. 

 Monthly maintenance should include the steps listed in this section AS WELL AS the 

steps listed in the “Daily Maintenance” section. 

 Intervals between monthly cleanings will depend on the duration that the stove is 

burning on a daily basis.  A stove which is operated continuously will need more 
frequent monthly cleanings than a stove which is used periodically as supplemental 
heat. 

 A good rule of thumb for monthly maintenance is that it should be done each time an 

entire ton of pellets is burned OR once per month, whichever comes first. 

 If excess ash accumulation is found in the exhaust chamber or venting system during 

monthly maintenance, the interval between cleanings should be reduced to eliminate 
the possibility of poor stove performance due to ash accumulation. 

Exhaust Chamber Cleaning 

The exhaust chamber of the stove was intentionally designed as an ash accumulation 

area.  Allowing ash to accumulate here prevents excess ash build‐up in the combustion blower 
and the venting system.  Similarly, the exhaust chamber is easily accessible via the two exhaust 
chamber clean‐out ports located in the firebox. 

 Using a 5/16” socket wrench, remove the two screws which hold each of the clean‐out 

covers in place.  The cleanout covers are located on the back wall of the firebox, near 
the bottom. 

 Remove the cleanout covers from the firebox and BEFORE vacuuming the chamber out, 

observe the type and quantity of ash build‐up.  The ash deposited in the exhaust 
chamber should be light, fluffy, grey or white in color, and should be no higher than half 
way up the clean‐out port. 

o

Do NOT allow the ash to accumulate higher than about half way up the cleanout 
port; significant ash accumulation in this area can “choke” the combustion 
blower and cause poor stove performance. 