18
Installation
Replacing Power Supply Modules
Installing a card
To install a card
1 Open the front door of the frame (see
2 To install a card into an empty slot, slide the card into the slot, and push gently on the
handle to seat the connectors.
Seating input cards requires more pressure. Inserting the card into the wrong slot will
not damage the card, and will be flagged by the on-card status LED flashing to indicate
that there is no connection to the rear panel.
3 Close the front door of the frame (see
Replacing Power Supply Modules
The Kaleido-MX frames support dual redundant hot-swappable power supplies. The basic
configuration includes a single supply, with an empty slot for the optional redundant
power supply. Installing a second power supply module and applying power to it
automatically engages the redundant supply mode. Each power supply has its own power
socket on the rear panel, and should be connected to the AC supply using the power cords
that shipped with your hardware, or other approved cords.
To install or change a power supply module in a Kaleido-MX (3RU)
1 Open the front door of the frame (see
2 Remove the controller card, to provide access to the power supply slots (see
3 Release the retaining spring by turning the captive screw mounted on the lower front
panel of the power supply counterclockwise.
4 Remove the power supply module by pulling on the handle on its front panel and
sliding it out of the frame.
5 Slide the new power supply module into the slot, and push it gently into position to
seat the connectors.
6 Secure the supply in position by turning the captive screw mounted on the lower front
of the power supply clockwise.
This engages a retaining spring which holds the supply securely in place.
7 Replace the controller card.
8 Close the front door of the frame (see
Notes
• A single power supply can be installed in either of the two slots.
• Power integrity is enhanced if the two power supplies are plugged into
different circuits.