beautypg.com

Data handling specifications, Ac power requirements, Chapter 4 – Grass Valley K2 Lx0 RAID Storage User Manual

Page 49: Data handling specifications ac power requirements, Chapter 4, k2, Chapter

background image

July 31, 2008

K2 Lx0 RAID Instruction Manual

49

Chapter

4

K2 Lx0 RAID Technical Specifications
and Operating Limits

Data handling specifications

AC power requirements

If one of the two power supplies fails, the remaining supply and cord must support the
full load. Your rackmount cabinet must include AC power distribution that can handle
these values.

Characteristic

Specification

Host interface

Fibre Channel

Data transfer rate

400 MB/s max

Number of host ports

2 ports per controller (L10, L20) 6 ports (Optional, an
additional 4 ports, L30)

Cache memory

1 GB (L10) 2 GB (20), 4 GB (L30)

Item

Measurement

Input voltage

100 to 240 VAC ±10% (x2), 50/60 Hz

Power consumption

a

Power supply

a.

For UPS choice, a safety allowance of 30% of the power consumption is necessary.

Power supply:
Basic cabinet: 2118 BTU/W
Expansion cabinet: 1470 BTU/W

Maximum power consumption

a.

Basic Chassis
L10, L10R, L20, L20R
configurations

SAS
AC: 610VA/590W
DC: 580W

SATA
AC: 550VA/530W
DC: 520W

Maximum power consumption

a.

Basic Chassis
L30, L30R configurations

SAS
AC: 640VA/620W
DC: 610W

SATA
AC: 570VA/550W
DC: 540W

Maximum power consumption

a.

Expansion Chassis
All configurations

SAS
AC: 610VA/590W
DC: 580W

SATA
AC: 550VA/530W
DC: 520W

Labeling according to the energy
saving act

Category: i
Energy consumption efficiency: 0.10