System cabling, Cable k2 summit 3g client, Cable dyno s controller – Grass Valley K2 Dyno S Quick Start v.3.0 User Manual
Page 10: Cable k2 summit 3g client cable dyno s controller

Chapter 1 Installation
System cabling
K2 Dyno S Replay System
10
Quick Start Guide
4 December 2012
System cabling
Cable K2 Summit 3G Client
Make K2 Summit 3G Client cable connections as illustrated.
NOTE: For Ethernet control, use the lower left port (as viewed from the rear).
Each channel can be both an input (record channel) and an output (play channel). For the
K2 Dyno S Replay System documented in this Quick Start Guide, C1 and C2 are record
channels and C3 and C4 are play channels.
For complete cabling instructions, refer to the K2 System Guide.
Cable Dyno S Controller
Make Dyno S Controller cable connections as illustrated.
The Ethernet connection between the K2 Summit 3G Client and the Dyno S Controller can
be via direct connect cable or via an Ethernet switch.
Channels (C1, C2, C3, C4) are bi-directional
Use C1 as record
channel. Connect
C1 SDI in 1
Use C2 as record
channel. Connect
C2 SDI in 1
Use C3 as play
channel. Connect
C3 SDI out 1
Use C4 as play
channel. Connect
C4 SDI out 1
Power
cord
Power
cord
Reference
Loop
AES audio
(1 for each
channel)
Keyboard
and mouse
(2 USB)
VGA
monitor
Ethernet control
connection
Optional:
Ethernet media
(FTP) connection
Power Cord
Power
Standby
Ethernet
(control)
Keyboard
Mouse
8681_02
Stereo
Audio Out
(1/8 in.)
DisplayPort
(use adapter if connecting
to a DVI or VGA monitor)